Appendix Geotechnical Investigation for Proposed Lost ,
Know More

This report summarizes the geotechnical investigation performed by URS Corporation (URS) for the proposed solar plant that NextLight Renewable Power, LLC (NextLight) is considering constructing near Lost Hills, California The project site is basically an open rectangular field measuring approximately one-half mile by one mile...

GEOTECHNICAL REPORT - Eskom
Know More

Eskom installations and power line servitude routes were considered Information collected during this investigation is suitable for site selection purposes, and once the final design is required, a Detailed Geotechnical Investigation will be required to provide design parameters and confirm findings of ,...

Geotechnical Engineering Report - aep
Know More

Geotechnical Engineering Report AEP Rockport Bottom Ash Complex Professional Engineering Certification Rockport, Indiana January 11, 2016 Terracon Project No N4155126 , 364, and 367 provided by AEP for the initial design of the power plant were included in this study The locations and logs of these previous borings are presented in...

GEOTECHNICAL INVESTIGATION GAS TURBINE POWER ,
Know More

GEOTECHNICAL INVESTIGATION GAS TURBINE POWER PLANT NILAND, CALIFORNIA 10 INTRODUCTION This report presents the results of our geotechnical investigation for the proposed Gas Turbine Power Plant in Niland, California The purpose of this investigation was to characterize the...

2016 ANNUAL DAM AND DIKE INSPECTION REPORT - ,
Know More

Annual Dam and Dike Inspection Report (2016) Cardinal Plant Page 1 of 12 10 INTRODUCTION This report was prepared by AEP- Geotechnical Engineering Services (GES) section, in part, to fulfill requirements of 40 CFR 25783 and the Ohio Department of Natural Resource (ODNR), Division of...

Geotechnical Investigation for Olien PV Solar Plant, Lime ,
Know More

Geotechnical Investigation for Olien PV Solar Plant PJ112/10/2013/04/2446 Page 5 SMEC South Africa Consulting Engineers 2446 Olien Solar Plant Reportdocx/rr/ 23 Drainage, Topography and Vegetation Ground levels on the site are in the order of 1450masl Drainage is generally in the form of sheetwash and the site is generally flat...

REPORT ON A GEOTECHNICAL INVESTIGATION FOR THE , - ,
Know More

REPORT ON A GEOTECHNICAL INVESTIGATION FOR THE PROPOSED NEW ESKOM GENERAL LANDFILL AND HAZARDOUS WASTE FACILITY, LEPHALALE 1 TERMS OF REFERENCE This report has been prepared at the request of Envirolution Consulting (Pty) Ltd and forms part of the specialist studies required for an Environmental Impact Assessment (EIA) It...